Basic Info.
Product Description
1. Features:
ADT horizontal torsion spring testing machine is an intelligent multifunctional measuring instrument designed and manufactured for testing and testing various torsion springs. It can be used for torque testing of various shapes of torsion springs, scroll springs and other elastic torsion pieces. It has the characteristics of simple operation, high precision, full function and convenient portability. It is widely used in various electrical, light industry, machinery manufacturing, scientific research Institutions and other industries.
2. Main features:
1. High precision, high resolution, fast sampling speed, large screen display.
2. The upper and lower limits can be set, with sound and light alarm function
3. Three parameters display (torque value, rotation angle, spring stiffness).
4. The three units N · m, kgf · cm and Ibf · in are mutually converted.
5. The three modes of real-time, peak and auto-peak can be switched at will.
6. Peak hold, automatic release function, free setting of release time.
7. Automatic shutdown function without operation, time can be set freely.
8. Large storage capacity, can save 99 sets of test data.
9. Automatic shutdown function without operation, time can be set freely.
10. Built-in micro printer (optional).
11. The USB interface communicates with the PC and can be connected to the computer for synchronous testing.
Three, specifications:
1. Measurement parameters:Parameter model | Maximum test torque | Measuring range | Minimum reading value (Nmm) |
ADT-500A | 500 mN. m | 5 ~ 500 (mN.m) | 0.01 mN. m |
ADT-1000A | 1000 mN. m | 10 ~ 1000 (mN.m) | 0.1 mN. m |
ADT-2000A | 2000 mN. m | 20 ~ 2000 (mN.m) | 0.1 mN. m |
ADT-3000A | 3000 mN. m | 30 ~ 2000 (mN.m) | 0.1 mN .m |
ADT-5000A | 5000 mN .m | 50 ~ 5000 (mN.m) | 0.1 mN. m |
ADT-1 | 1 N .m | 0.01 ~ 1 (N.m) | 0.0001 N .m |
ADT-2 | 2 N. m | 0.02 ~ 2 (N.m) | 0.0001 N. m |
ADT-5 | 5 N .m | 0.05 ~ 5 (N.m) | 0.0001 N. m |
ADT-10 | 10 N. m | 0.1 ~ 10 (N.m) | 0.001 N. m |
ADT-20 | 20 N .m | 0.2 ~ 20 (N.m) | 0.001 N .m |
ADT-30 | 30 N .m | 0.3 ~ 30 (N.m) | 0.001 N. m |
ADT-50 | 50 N .m | 0.5 ~ 50 (N.m) | 0.001 N .m |
2. Angle resolution: 0.1 °
3. Range of measurement angle: 0 ~ ± 9999.9 °
4. Rotation diameter of test piece: φ100mm
5. Length of test piece: 150mm
6. Loading method: manual
7. Accuracy: ± 1%
8. Power supply: AC220V 50Hz
9. Overall dimensions: 710 × 320 × 290 (mm)
10. Weight: about 37.5Kg
Fourth, the product schematic 1. LCD screen 2. Setting parameter name column 3. Function buttons
4. Special test head 5. USB interface 6. Power socket
Five: display panel
Six: Key description
1. ON / OFF key: can be used to turn on and off.
2. Angle reset key: during real-time measurement, press this key to correct the angle zero point.
3. View key: This key can be used to view the stored measurement data during the measurement interface.
4. Clear key: during real-time measurement, press this key to correct the torque zero point. During peak and auto peak, press this key to clear the peak and return to zero; when viewing the interface, press this key to clear the current stored measurement value, long press this key to clear all stored measurement values. In the user setting interface, press this key to return to the previous interface without saving data.
5. Peak key: It is used to switch between the three measurement modes of real-time, peak and auto-peak in the measurement interface, and has an up-shift function in the setting interface. In the view interface, press this key to view the previous data.
6. Save key: It is used to save the measured data in the measurement interface, and has the function of moving down in the setting interface.
In the view interface, press this key to view the next data.
7. Print key: On the measurement interface, press this key to print the stored measurement value (except for those without a print function). It has a left-shift function in the setting interface.
8. Unit key: Used to switch between N · m, kgf · cm and Ib · in three units during the measurement interface. It has a right shift function in the setting interface.
9. Setting key: users can enter the setting menu through this key in the measurement interface, and press this key to save data when setting data.
Seven: User operation instructions
Display product name, model and version information
2. The main user interface display 3. User setting interface
Press the setting key once, the display is as follows:
Use the up or down key to select the setting item. When the user's setting item is selected, press the setting key to enter the parameter setting interface.
4. Parameter setting interface
In the user setting interface, press the setting key to enter the parameter setting interface and display as follows:
Description of setting parameters: (Take the maximum torque value as an example)
Use the up and down keys to shift and modify the data. At this time, press the set key to confirm and save the set data, (if you press the zero key to return, the data will not be modified). The set data cannot exceed the maximum load value.
(1) Maximum torque value: The user sets the upper limit value of the torque, which can be freely set as required. When the upper limit value is reached, the number above the parameter name \"torque upper limit value \" flashes and the buzzer alarms. The upper limit value is not higher than full scale.
(2) Minimum torque value: The user sets the lower limit value of torque, which can be freely set as required. When the lower limit value is reached, the number above the parameter name \"torque lower limit value \" flashes. The lower limit value shall not be higher than the set upper limit value.
(3), minimum storage value setting: the user sets the minimum storage value according to storage needs, data less than this value will not be stored.
8. Other function description
1. Description of printing function: print data through micro printer.
2. Communication: communicate with the host computer via USB. The communication protocol adopts MODBUS-RTU protocol.
3. Save data: save the data during measurement through the save key.
4. View stored data: View the stored data through the view button.
5. Alarm description: when the measured value exceeds the upper limit, the upper limit indicator will be displayed, and the buzzer will also give an alarm; when the measured value is lower than the lower limit, the lower limit indicator will be displayed. When the measured value exceeds 120% of the maximum load, the sensor may be damaged. When the \"Overload \" warning prompt appears, the machine enters the automatic protection state, you must press the reset button or restart, if you can not measure, please long press the set button, enter the password: up, down, press the set button Restore the factory settings interface, choose to restore the factory settings, press the setting button to restore (if you can not restore, please contact the manufacturer).
Nine, operating environment
1. Operating temperature: -10 ºC ~ 40 ºC.
2. Operating humidity: ≤90% RH.
3. There is no vibration source and no corrosive environment around.
4. Minimum peak hold value setting: the user needs to set freely according to the peak value, automatic peak measurement, data less than this value will not be saved by the peak value.
5. Maximum deformation angle setting: The user sets the maximum value of the angle, which can be freely set as required. When the upper limit value is reached, the number above the parameter name \"angle maximum value \" flashes.
6. Minimum deformation angle setting: the user sets the minimum angle, and can freely set it as required.
7. Automatic peak time setting: the user can set the time from 1 second to 99 seconds freely according to the peak time required for automatic peak measurement.
8. Automatic shutdown time setting: under no operation state, the automatic shutdown time can be freely set from 1 minute to 99 minutes.
9. Gravity acceleration setting: The user can set the gravity acceleration value according to the location of the region. The machine defaults to 9.794.
10. Restore the initial setting: improper user operation or chaos when changing the data multiple times, you can use this setting to restore the data of 1 ~ 9 to the factory state.
10. Operation steps
1. Under normal circumstances, plug in the power cord, turn on the power switch, and after the display is stable, if the display data is not zero, please press the\"\" Zero\"\" key to clear and clear the torque value.
2. According to the test needs, press the moment unit conversion key to select the required unit.
3. Set up before the test, the specific steps such as parameter setting interface.
Twelve, torsion spring torque test procedure
1. According to the test requirements, select the appropriate mandrel and install the mandrel to the mounting holes of the test heads on both sides.
Then install the spring under test on the main test mandrel, one end of which is fixed by the secondary mandrel.
2. Shake the handle to make the third mandrel contact with the other end of the torsion spring, and the force value and angle will be cleared at the same time just after contact.
3. The torque value and angle value displayed on the LCD screen are zero.
4. According to the torsion spring measurement requirements, rotate the measuring handle smoothly and evenly to display the technical parameters of the torsion spring being tested.
5. Repeat the above operation to verify the technical parameters of the torsion spring.
14. Precautions, maintenance and repair
1. Do not overload the torque test, be sure to test the torque within the test range of the torque tester, otherwise the instrument will be damaged and more likely to be dangerous.
2. Do not tap the LCD screen to place objects on the LCD screen.
3. Do not press the function keys with nails, sharp objects or pointed objects.
4. Do not use the torque tester in the place where water, oil or other liquids are splashed.
Cool, dry and free from vibration.
5. Do not loosen the fixing screws of the torque test head.
6. Do not use other power sources than the rated voltage, otherwise it may cause electric shock or fire.
7. Please do not pull out or insert the plug with wet hands, otherwise it may cause electric shock.
8. Please clean the machine with a soft cloth, immerse the dry cloth in the water soaked with detergent, wring it out to remove dust and dirt. Do not use chemicals that are easily emitted, such as volatile oil, thinner, alcohol, etc.
9. Handle gently during use and handling.
10. Do not disassemble, repair or modify the machine by yourself. These actions may cause permanent malfunction of the instrument.
11. Please contact the original place of purchase or our company if a fault occurs.
12. Within one month from the date of sale, the product has quality problems under normal use and no damage to the appearance. The customer shall return the original specification of the sales invoice, valid warranty card and complete packaging to the original place of purchase or the company to replace the same specifications For the model product, the replacement product will continue the warranty period and terms of the original product.
13. This product is within one year from the date of sale. Under normal use, non-human faults are covered by the warranty (the user does not disassemble the machine or repair the company at other repair points. The company does not guarantee it). If the card is contacted with the original place of purchase, the company will get a free warranty for one year.
14. The warranty terms of this product are only applicable to the ANH series products sold in the Chinese market. For products that exceed the replacement period and warranty period, the customer can check the original purchase place for maintenance or contact the company, and the company provides paid repair .
Other supporting instrumentsequipment name | model | equipment name | model |
Digital push-pull force gauge | HF | Electric vertical machine | AEV |
Pointer push-pull force gauge | NK | Electric single column vertical machine | AEL |
Digital torque tester | ANL | Electric horizontal machine | AEH |
Bottle Cap Torque Tester | ANL-P | Spiral side roll test machine | ASC |
Pointer torque screwdriver | ANQ | Manual horizontal test stand | AMH |
High-speed impact torque tester | AGN | Manual vertical and horizontal test stand | ASL |
Dynamic torque tester | AND | Hand-pressed tensile and compression test stand | AST |
Torque wrench tester | ANJ | Spiral tension and compression test stand | ALX |
Torsion spring testing machine | ANH | Special testing machine for peeling force | ABL |
Spring tension and compression testing machine | ATH | Ball pressure test device | AQY |
Shore Rubber Hardness Tester | LX | Motorized hydraulic tension and compression test stand | ALR |
Shore Hardness Test Stand | LAC-J | Button Tester | ABQ |
Fruit Hardness Tester | AGY | Terminal tensile tester | ADL |
Fruit Hardness Tester Stand | GYJ | Rope tension meter | ASZ |
Tonometer | ATN | Side pressure tension tester | HD |
Address:
a-4035 Ruifeng Business Expo, Wuhu City, 241000, Wuhu, Anhui, China
Business Type:
Manufacturer/Factory
Business Range:
Industrial Equipment & Components, Instruments & Meters, Service
Management System Certification:
ISO 9001, ISO 9000, ISO 14000, ISO 20000, QC 080000
Company Introduction:
Mikrosize focus on measuring and testing precision instruments.
Mikrosize is mainly researching, producing, selling manual video measuring system, CNC video measuring system, Instant video measuring machine, Digital vertical profile projector, Digital horizontal profile projector, Rockwell hardness tester, brinell hardness tester, Vickers hardness tester, Universal hardness tester, and Metallographic Equipments such as Metallographic Cutting Machine, metallographic mounting press, metallographic grinding and polishing machine etc.
Mikrosize is committed to make measurement more precised and efficient.
Thanks for visiting Mikrosize website!